CMM-15 Oil Degassing Plant
CMM-15 Oil Degassing Plant
- Description
- Specification
- Advantages
- Application
- Configurator
- Webinars
- Payback Period
- Video
- Publications
The CMM-15 plant is designed for degassing, removal of solids and heating of oil for power transformers with voltage up to 1,150 kV. The processing capacity of the machine is 15,000 liters per hour.
The CMM-15 plant is built as a self-contained unit with all components and operating assemblies protected by metal panels and easy opening gas-spring loaded doors on the sides and back of the unit.
The unit consists of a vacuum chamber, input and output oil pumps, coarse and fine filters, oil trap, oil heater, pipelines with valves, vacuum pump section and a control cabinet.
| № |
Parameter |
Value |
| 1 | Capacity (degassing, drying and filtration mode), m3/hour (gpm) |
15 (66) |
| 2 | Capacity (heating and filtration mode), m3/hour (gpm) |
17 (74.84) |
| 3 | Processed oil parameters*:
|
0.1 10 ppm or 5 ppm or 5 ppm+ (optionally) 1 |
| 4 | Oil output temperature in heating mode, ºС (ºF) |
90 (194) |
| 5 | Outlet pressure, MPa (psi) |
58 (0.4) |
| 6 | Max power, kW |
205 |
| 7 | Residual pressure in vacuum chamber during degassing, Pa (psi) |
267 (0.039) |
| 8 | Residual pressure in vacuum chamber during air tightness test, Pa (psi) |
26.7 (0.0039) |
| 9 | Power supply parameters |
Any options on customer’s request |
| 10 | Dimensions, mm (in) | |
| — length |
4,365 (172) |
|
| — height |
2,270 (89) |
|
| — width |
2,300 (91) |
|
| 11 | Weight, kg (lbs) |
3,100 (6,834) |
Note: * initial oil parameters:
- volumetric gas content – below 5%;
- mass moisture content – below 01% (100 g/ton);
- temperature – above 0 ºС/ 32 ºF.
**All equipment sold in the USA is designed to operate on 60 Hz AC Power
- versatility;
- no need to use adsorbents for transformer oil drying;
- no air pollution and no waste streams to dispose of or store;
- simple operation and servicing;
- best oil quality even after one processing cycle;
- low power requirements;
- low noise levels.
Components type is basic
Components type is premium
Manual performance adjustment by valves (or smooth performance adjustment, see option). Functioning in semi-automatic modes. Stepped or smooth (see option) oil heating. PLC control
Automatic performance adjustment. Functioning in automatic modes. Smooth oil heating. Control from PLC + HMI
Performance adjustment with manual valves
Performance adjustment of the oil pump is executed with a regulator on the control panel by means of a valve with an electric drive. Visual monitoring of the flow rate is by the flow meter indicator
Performance adjustment of the oil pump is executed by setpoint selecting at the control panel screen for maintaining the level in the vacuum column. Pump operation is smooth throughout the entire control range. There is a digital meter to control oil flow
The controller program switches the heater stages by contactors according to the algorithm. Operator sets the temperature and it is kept constant automatically
Solid state relay (SSR) adjusts the heater stages’ current smoothly and non-contactly. The P-Int-Derivative Controller
The language of text at the controller screen, devices, controls and the language of the technical documentation is English
The language of text at the controller screen, devices, controls and the language of the technical documentation is Spanish
The 10 ppm mode is the standard operating mode of the equipment, which involves drying oil using thermal vacuum technology.
The 5 ppm mode ensures a very low level of residual moisture in the oil by reducing machine productivity. This means that the equipment effectively removes even the smallest traces of water, which significantly extends the service life of the equipment.
The 5 ppm+ mode is an improved version that ensures even lower residual oil moisture levels by using sorbent cartridges and reducing machine productivity. This is ideal for critical applications especially for heavily loaded transformers with high demands.
Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit
Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which was processed by the unit
Capacitive transducer determines the activity of water dissolved in the oil and converts it into the absolute moisture content of the oil which entered the unit and which was processed by the unit
Mechanical flow meter with total flow display
Digital flow meter with current and total flow display
The cable is fitted with an industrial sealed connector, consisting of an internal plug and a cable socket
The cable wires’ ends are fitted with a crimp terminals
The cable is fitted with an industrial sealed connector, consisting of an internal socket and a cable plug
No publications found.